What was found
REWORK: MAIN DECK FLOOR SEAT TRACK FOUND CORROSION AT STATION 1620 - 1661 , X = 75.25 . MAIN DECK FLOOR AT SEAT TRACK STATION 1620 TO STATION 1661 X = 75.25 , CORROSION FOUND EXFOLIATED AND EXCEED LIMIT AS PER SRM 53-00-52-1A FIGURE 101 ALLOWABLE DAMAGE 1 . CORRODED SEAT TRACK REPAIRED BY SECTIONAL SEAT TRACK REPLACEMENT FROM STATION 1611 TO STATION 1671 X = 75.25 AS PER SRM 53-00-52-2R FIGURE 201 REPAIR 1 . REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 .