What was found
MDIS 728 21-26 4813 26OCT19 MEM OPEN U WHILE PREFORMING "FLIGHT COMPARTMENT AND ELECTRONICS RACKS AIR DISTRIBUTION - ADJUSTMENT/TEST" AMM 21-21-00-05, CBS: EXTRACT FAN HI SPD, HI SPD, STBY PITOT SUPPLY, FAN SUPPLY LO SPD, 105 XP BUS BAR, HYD PUMP POPPED. BURNT SMELL AND SMOKE CAME FROM ELECTRONIC BAY. WATER DRIPPING IN THE ELECTRONIC BAY L/H SIDE. EXTERNAL POWER IS OFF. WIRE BUNDLE ABOVE 101VU PANEL HAS MULTIPLE WIRES EXPOSED AND BURNED. ACT 07NOV19 21:14 MEM SEE THE FOLLOWING WRI'S FOR WORK ACCOMPLISHED RELATED TO THIS WRI: 24-20/4814, 05-50/4818, 53-10/4820, 53-00/4822, 53-10/4823, 25-20/4824, 25-10/4829, 24-20/4831, 24-20/4834, 21-20/4836, 25-20/4835, 24-30/4816, 24-20/4814, 21-20/4836, AND MTSI 53-10/4821. SEE THE FOLLOWING WRI'S FOR OPERATIONAL CHECKS: 21-97/4842, 24-97/4837, 28-97/4839, 29-97/4838, 30-97/4840, 31-97/4847, 32-97/4843, 33-97/4845, 49-97/4846, 73-97/4847, AND 79-97/4844.