What was found
UPON REMOVED MAIN DECK DELAMINATED FLOOR PANEL #282JF FOR REPLACEMENT FOUND MAIN DECK FLOOR SEAT TRACK AT STATION 1791 X=-75.25 FLANGE CORRODED. MAIN DECK FLOOR SEAT TRACK AT STATION 1791 X=-75.25 FLANGE CORROSION REMOVED AND FOUND EXCEED LIMIT AS PER MD-11 SRM 53-00-52-1A FIGURE 101 ALLOWABLE DAMAGE 1, ORIGINAL MATERIAL THICKNESS: 0.080" MATERIAL REMOVED: 0.052" MATERIAL REMAINING: 0.028". SEAT TRACK REPAIR CARRIED OUT AT STATION 1751 TO STATION 1811, X=-75.25 AS PER MD-11 SRM 53-00-52-2R FIGURE 201 REPAIR 1. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.