What was found
MAIN DECK FLOOR SEAT TRACK AT 755 X=-47.5 FOUND CROWN DAMAGED. DAMAGED AREA EVALUATED AND FOUND EXCEED LIMITS IAW SRM 53-00-52-1A, FIGURE 101, ALLOWABLE DAMAGE 1. SEAT TRACK REPAIR CARRIED OUT IAW SRM 53-00-52-2R FIGURE 201 REPAIR 1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.