What was found
FWD WET AREA BETWEEN STA 324-345 LBL 39 FLOOR SUPPORT CORRODED. REMOVED CORR ON FLOOR SUPPORT STA 324-345 LBL 39 IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51-1A FIG 101. REMOVED, LOCATED, DRILLED AND INSTALLED NEW FLOOR SUPPORT IAW SRM 51-40-02 AND DEG 141N5170 REV C.