What was found
MAIN DECK FLOOR PANEL 231JG IS TORN AT FASTENER HOLE. FABRICATED NEW PANEL 231JG, LOCATED AND DRILLED HOLES INSTALLED INSERTS AND APPLIED EDGE POTTING RESTORED FINISH AND PART MARKED IAW SRZ 25-005 REV R, AMM 51-75-10, GMM 07-0-1000.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOOR PANEL 231JG IS TORN AT FASTENER HOLE. FABRICATED NEW PANEL 231JG, LOCATED AND DRILLED HOLES INSTALLED INSERTS AND APPLIED EDGE POTTING RESTORED FINISH AND PART MARKED IAW SRZ 25-005 REV R, AMM 51-75-10, GMM 07-0-1000.