What was found
MAIN CARGO DECK, STA1335 LBL105 TO LBL113, CENTER WING UPPER PANEL HAS CORROSION (MARKED) REMOVED FASTENERS, REMOVED CORROSION, NDT CHECK FOR MATERIAL LOSS, FOUND AREA TO BE WITHIN ALLOWABLE LIMITS PER SRM 57-10-01-1A FIG 101 & EA # 1-5710- T03511416, PART 1. TREATED, PRIMED, RE-INSTALLED FASTENERS AND VAPOR BARRIER APPLIED.