What was found
CABIN - MAIN DECK CARGO COMPARTMENT EXISTING OUTER REPAIR ANGLE CHAFFED AT LEFT HAND STATION 535 , LONGERON 19 LEFT . CABIN - MAIN DECK CARGO COMPARTMENT AT LEFT HAND FRAME STATION 535 LONGERON 19 LEFT CHAFFED MARK AT EXISTING OUTER REPAIR ANGLE FOUND TO EXCEED LIMIT AS PER SRM 53-00-00-2R FIGURE 205 ALLOWABLE DAMAGE . EXISTING OUTER CHAFFED REPAIR ANGLE REMOVED AS PER SRM 51-33-01-0G AND REPAIRED AS PER SRM 53-20-07-2R FIGURE 202 REPAIR 1 . REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 .