What was found
MAIN DECK STA 1055 BETWEEN BL0-RBL 24.75 FLOOR SUPPORT CORRODED. ACCOMPLISHED IAW EA F-5310-T0352036 P1 FUSELAGE - MAINFRAME -MAIN CARGO FLOOR SUPPORT STA 1055 CORRODED, NEW PART FABRICATION TEMPER ATERATION, REMOVED CORR IAW SRM 51-10-02-OG, FOUND TO BE OUT LIMITS IAW SRM 53-00-51-1A FIG 101 DETAIL VI. REMOVED, FABRICATED AND INSTALLED FLOOR SUPPORT IAW SRM 51-40-02-OG, 51-40-05-OG, 51-40-08-OG AND DWG 144N5005 REV - AND REV A.