Service difficulty report · Line · Boeing 7572Y0

Difficulty date
February 12, 2020
Submitted
February 14, 2020
Operation
Air carrier
Aircraft
N930FD
Make and model
Boeing 7572Y0
Aircraft serial
25240
Aircraft time
64,438 hours, 23,277 cycles
Part
Line
Part number
271N66111020
Condition
Leaking
Location
Hyd System
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKEOFF, RAISED GEAR HANDLE TO UP. RECEIVED A GEAR DOORS EICAS AND DOORS LIGHT. COMPLED WITH QRH. NO OTHER ASSOCIATED PROBLEMS. PERFORMED B757 FIM 32-09 FT804, PSEU BITE TEST, NO HISTORY FAULTS STORED OR CURRENT FAULTS PRESENT AT THIS TIME. FAULT IS NOT PRESENT ON EICAS AT THIS TIME. SUSPECT HYD LEAK ON RT GEAR WAS REASON FOR GEAR DOORS EICAS MESSAGE. TEMP INSTALLED 3 FLEX HYD LINES IN PLACE OF RIGID LINES IN ORDER TO CONTINUE T/S OTHER DISCREPANCIES. BLED THE TEMP INSTALLED LINES GOING TO THE TRUCK POSITION ACTUATOR. ERS 20-00566 IS SUBMITTED FOR APPROVAL TO USE THE 3 HYD FLEX LINES FOR REPAIR OF LEAKING RIGID LINE ON RT MLG. AWAITING RESPONSE. TEMP FLEX LINE INSTALLED FOR RT GEAR TILT ACTUATOR OK PER E.A. F-2902-T0352405 COMPLIED WITH INSTALLATION OF 3 EA HYD FLEX LINES, P/N 171141-6CR-0360, 171141-6CR-0120, AND 171141-6CR-0300, WITH 2 UNIONS MS21902-6J, IN PLACE OF RIGID LINE, P/N 271N6611-1020, ON RT MLG REF EA F-2902-T0352405 PT 1 AND B757 AMM 20-10-09-8. LEAK CHECK GOOD AT THIS TIME.