What was found
DURING ACCOMPLISHMENT OF HIGH FREQUENCY EDDY CURRENT INSPECTION ON LEFT HAND SIDE FUSELAGE SKIN COMMON TO UNDERWING LONGERON, FOUND 02 CRACK INDICATION AROUND FASTENER HOLES AT STATION 1024 AND STATION 1032, STRINGER 37 LEFT, APPROXIMATE 0.8" AND 1" IN LENGTH AS MARKED. WORK ACCOMPLISHED AS PER EA G 5310-T0352363 P1. TITLE: FUSELAGE - MAINFRAME - LEFT HAND UNDERWING LONGERON MODIFICATION - SB777-53-0087 RO. STEP 19. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.