What was found
HFEC INSPECTION CARRIED OUT ON NOSE LANDING GEAR RIGHT HAND TRUNNION FITTING EXISTING TRIMMED OUT AREA CRACK GROWTH APPROXIMATE 0.25 INCHES AT STATION 595 . NOSE LANDING GEAR RIGHT HAND TRUNNION FITTING EXISTING TRIMMED OUT AREA CRACK GROWTH APPROXIMATE 0.25 INCHES AT STATION 595, CARRIED OUT REPAIR AS PER SRM 53-10- 14-2R FIGURE 202, REPAIR 2. INITIAL INSPECTION TO BE CARRIED OUT AT 1,500 FLIGHT CYCLES AFTER REPAIR AND REPETITIVE INSPECTION TO BE CARRIED OUT EVERY 1,500 FLIGHT CYCLES AS PER SRM 53-10-14 TABLE 201, FIGURE 202 REPAIR 2. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.