What was found
L1 DOOR HOLD OPEN LOCK COLLAR BROKEN. REMOVED PANEL 221AL TO GET ACCESS TO COLLAR AS PER MM 52-11-08-4. INSTALLED COLLAR AND CATCH ASSY AS PER AMM 52-11-08-8. OPS CHECK OK. STILL NEED TO INSTALL THE 221AL PANEL WHICH STILL IN LEAD OFFICE. INSTALLED PANEL 221AL AS PER MM 52-11-08-4. SEALANT APPLIED, OPENED ANOTHER WRI (53-50/6425) TO MONITOR SEALANT CURING. ITEM CLOSED.