What was found
PDIS 572 30-20 5311 31MAR20 CGN OPEN U LOGPAGES:3248069 ON TAKE OFF RECEIVED LEVEL 1 "ENG 2 ANTI-ICE OFF" WITH A DISAGREE LIGHT. THIS WAS WITH ENG #2 ANTI-ICE VALVE SELECTED ON. SWITCHED THE VALVE OFF AND RECEIVED A LEVEL 1 "ENG 2 ANTI-ICE DISAG" DUMPED 15 K SHUTDOWN ENG #2 SHGN 31MAR20 15:36 CGN REMOVED AND REPLACED #2 ENGINE ANTI ICE VALVE AS PER AMM 30-22-01-4-1. ITEM REMAINS OPEN. TEST TO BE CARRIED OUT. FACT 31MAR20 16:50 CGN CARRIED OUT #2 ENGINE/INSPECTION AND POST- WINDMILL INSPECTION IAW AMM 72-00-05-6-1. RAN #2 ENG IAW MD-11 JRH. ALSO ACCOMPLISHED #2 ENG NOSE COWL ANTI-ICE TEST DURING ENGINE OPERATION, ALL PARAMETERS NORMAL. A/C OK TO CONTINUE SERVICE.