Service difficulty report · Floorbeam · Airbus A300F4605R
FAA SDR system
- Difficulty date
- April 17, 2020
- Submitted
- April 21, 2020
- Operation
- Air carrier
- Make and model
- Airbus A300F4605R
- Aircraft serial
- 726
- Aircraft time
- 35,467 hours, 19,236 cycles
- Part
- Floorbeam
- Part number
- A53974225236
- Condition
- Corroded
- Location
- Fuselage
- Stage of operation
- IN
- How discovered
- V
- Nature of condition
- O
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FUSE INTR STRUCTURE FR 69, ABOVE STGR RH 51 FLOOR BEAM HAS INTERGRANULAR CORROSION. REMOVED CORR. FOUND OUT OF LIMITS. CUT OUT DAMAGE IAW SRM 51-73-10 & 53-10-15. RECEIVED REPAIR ANGLE ON TRAVELER # T20/1486890 & REPAIR SPLICE ON TRAVELER # T20/1486887. FABRICATED BEAM REPAIR IAW SRM 53-10-15 FIG 208. INSTALLED REPAIR IAW SRM 53-10-15 FIG 208. PART MARKED IAW GMM 07-0-1001. CAT "A" REPAIR, FRAME 69 R/H. "MAJOR REPAIR"