What was found
DURING HIGH FREQUENCY EDDY CURRENT OPEN HOLE INSPECTION CARRIED OUT AS PER EARN NR - 0015 REQUEST ON ALL FASTENER HOLES AT LEFT HAND BANJO FITTING FORWARD AND AFT REPAIR AREA STATION Y = 2164 AND FOUND NUMBER 4 HOLE FROM BOTTOM UP AT AFT ROW WITH DAMAGE INDICATION. LEFT HAND BANJO FITTING AFT EXISITING REPAIR AREA STATION Y = 2164 NUMBER 4 HOLE FROM BOTTOM UP AT AFT ROW AREA 01 EACH DAMAGE FASTENER HOLE REPAIR CARRIED OUT AS PER ENGINEERING AUTHORIZATION 1-5530-T0354042 PART 1 TITLE : STABILIZERS - VERTICAL STABILIZER - CRACK REPAIR ON VERTICAL STABILIZER REAR SPAR LT FWD AND AFT FLANGES. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100. REFER TO SPECIAL NONROUTINE MAINTENANCE FORM N01287 FOR WORK DETAILS.