As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FORWARD WET AREA STA 375 LBL 20 FLOOR SUPPORT CORRIER AREA. REMOVED CORROSION FWD WET AREA STA 375 LBL 20 FILLER IAW B 757 SRM 51-10-02-OG ORIGINAL MATERIAL .071",MAT REM .058",MAT LOSS .013" FOUND TO BE OUT OF LIMITS IAW B 75 757 SRM 53-00-51-1A FIG 101 DET VI.REMOVED FILLER IAW B 757 SRM 51-40-02-OG,FABRICATED & INSTALLED FILLER PER VENTURA AEROSPACE DWG 3471 REV B AND 3470 REV B