What was found
MAIN DECK: FLOOR BOARD SUPPORT ANGLE AT APPROX STA 435 (INBD OF L1 DOOR) APPROX LBL 74-88 IS CORRODED AND EXFOLIATED (MARKED AND DOT 67). REMOVED AND REPLACED FLOOR SUPPORT ABA8355-1 REF DAC DWG SP11530074 AND SRM 51-31-01-OG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK: FLOOR BOARD SUPPORT ANGLE AT APPROX STA 435 (INBD OF L1 DOOR) APPROX LBL 74-88 IS CORRODED AND EXFOLIATED (MARKED AND DOT 67). REMOVED AND REPLACED FLOOR SUPPORT ABA8355-1 REF DAC DWG SP11530074 AND SRM 51-31-01-OG.