What was found
RIGHT HAND WING TRAILING EDGE - OUTBOARD FLAP VANE NR 3 FROM INBOARD FITTING FOUND WITH HOLE CORRODED. CORROSION AROUND HOLE AT THE RIGHT WING TRAILING EDGE OUTBOARD FLAP VANE NR 3 FROM INBOARD FITTING REWORKED AND FOUND EXCEEDS IAW SRM 57-50-02-2R, REPAIR 5, FIGURE 201. OVERSIZED BUSHING FABRICATED IAW SRM 57-50-02-2R, REPAIR 5, FIGURE 201, AND EA. 1-5750-T0354672, PART 1, STEP 1A. OVERSIZED BUSHING INSTALLED IAW AMM 27-50-32-4. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100.