What was found
RIGHT HAND WING TRAILING EDGE - OUTBOARD FLAP VANE NR 5 FROM INBOARD FITTING FOUND CORRODED AROUND HOLE. CORROSION AROUND HOLE WAS REWORKED AND FOUND EXCEEDED LIMITS IAW SRM 57-50-02-2R, REPAIR 5, FIGURE 201. AN OVERSIZED BUSHING WAS FABRICATED IAW SRM 57-50-02-2R, REPAIR 5, FIGURE 201, AND EA 1-5750-T0354672, PART 1, STEP 1A. THE OVERSIZED BUSHING WAS INSTALLED IAW AMM 27-50-32-4. THE REPAIR WAS CLASSIFIED AS MINOR IAW GMM 6-2-100.