What was found
MAIN CARGO FLOOR SUPPORT ANGLE HAS MULTIPLE DRILL START/TOOLING MARKS @ RBL- 64 STA. 920 TO STA. 1000 BLENDED OUT TOOLING MARKS AT MAIN CARGO FLOOR SUPPORT (CREASE BEAM) AT STA.920 TO STA. 1000 RBL 64 AND FOUND OUT OF LIMITS IAW B757 SRM 53-40-13-1A FIG 101 DET VIII, REMOVED AND REPLACED BY FABRICATION CREASE BEAM FROM STA. 900 TO STA 1040 RBL 64 IAW B757 SRM 51-40-05, 51-20-01, 51-40-02 AND BOEING DWG # 144N5140 REV A