What was found
CABIN AT R3 PLUG DOOR NR 1 STOP BEAM FOUND CRACKED AT AFT. CABIN AT R3 PLUG DOOR, CRACKED NR 1 STOP BEAM REMOVED AND REPLACED AS PER SRM 51-31-01-0G. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN AT R3 PLUG DOOR NR 1 STOP BEAM FOUND CRACKED AT AFT. CABIN AT R3 PLUG DOOR, CRACKED NR 1 STOP BEAM REMOVED AND REPLACED AS PER SRM 51-31-01-0G. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.