What was found
HIGH FREQUENCY EDDY CURRENT INSPECTION CARRIED OUT AT LEFT HAND SIDE OF THE LOWER VERTICAL STABILIZER FORWARD FLANGES OF UPPER REAR SPAR CAP STATION 2164 AND FOUND CRACK INDICATION. FOUND THE BANJO FITTING CRACKED APPROXIMATE 1/4" TRIMMED AS PER SRM 55-30-02- 2R FIGURE 201 REPAIR 5 AND REPAIR CARRIED OUT ON LEFT HAND # 4 BANJO FITTING AS PER SRM 55-30-02-2R FIGURE 202 REPAIR 5. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100. TO CARRY OUT INITIAL INSPECTION AT 5400 FLIGHT CYCLES AND REPETITIVE INSPECTION AT EVERY 2700 FLIGHT CYCLES AS PER SRM 55-30-02-2R TABLE 203 REPAIR 5 FIGURE 202 REQUIREMENTS.