What was found
CABIN, UPON REMOVAL OF FLOOR PANEL FOR ACCESS FOUND FLOOR SUPPORT CORROSION AT STATION 1887 - STATION 2007, X = - 25. CORROSION EVALUATED, FOUND EXFOLIATED AND EXCEEDED LIMIT AS PER SRM 53-00-00-2R FIGURE 206 ALLOWABLE DAMAGE. CORRODED FLOOR SUPPORT AT STATION 1887 TO STATION 2007 X = - 25 REMOVED AND REPLACED AS PER SRM 51-31-01-0G. FLOOR SUPPORT FABRICATED BY MACHINING AS PER DRAWING AGA 7087 REVISION M. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2- 100.