What was found
DURING ACCOMPLISHMENT OF SPECIAL/NONROUTINE MAINTENANCE FORM NUMBER: N00325, HIGH FREQUENCY EDDY CURRENT INSPECTION CARRIED OUT AT NOSE LANDING GEAR RIGHT HAND TRUNNION FITTING STATION 583 AND FOUND LONGERON IN THE TRIMMED AREA WITH CRACK INDICATION PROPAGATE FROM THE LOWER FASTENER HOLE APPROXIMATELY 0.250 INCHES LENGTH. NOSE LANDING GEAR RIGHT HAND TRUNNION FITTING AT STATION 583 X = - 24 ATTACH AREA CRACKED LONGERON REMOVED AND REPLACED WITH NEW LONGERON AS PER SRM 51-31-01- 0G . REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100 .