What was found
TRAPPED WATER INDICATION ON ELEVATOR UPPER SKIN PANEL HONEYCOMB CORE CELLS. LOCATED AT 8 INCH OUTBOARD FROM RIB 16 AND 8 INCH FROM TRAILING EDGE ON LT HORIZONTAL STABILIZER (1EA) (L=2 INCH. W=1.8 INCH). REPAIRED LT ELEVATOR UPPER SKIN PANEL HONEY COMB CORE CELL LOCATED BETWEEN ERIB 16 AND ERIB 17 AT 7.9 INCHES FROM ERIB 16 AND 7.25 INCHES FROM T/E ON LT HORIZONTAL STABILIZER, AS PER A300 SRM 55-21-12 PAGE BLOCK 201 PARAGRAPH 5.J. EXACT LOCATION IS STATION 757 AND STATION 833, AS PER AMM 06-31-55-00 AND EA 6-5520-T0355929 (P1). THIS REPAIR IS CAT-A.