What was found
TRAPPED WATER INDICATION ON ELEVATOR UPPER SKIN PANEL HONEYCOMB CORE CELLS. LOCATED AT 10 INCH INBOARD FROM RIB 16 AND 15 INCH FROM TRAILING EDGE ON LT HORIZONTAL STABILIZER (1EA) (L=3.5 INCH. W=2.25 INCH). REPAIRED LT ELEVATOR UPPER SKIN PANNEL HONEYCOMB CORE CELLS LOCATED BETWEEN ERIB 17 AND RIB 18 AT 1.35 INCH FROM ERIB 17 AND 15.28 INCH FROM T/E ON LT HORIZONTAL STABILIZER, AS PER A300 SRM 55-21-12 PAGE BLOCK 201 PARAGRAPH 5.J. EXACT LOCATION IS BETWEEN STA 800 AND STA 833, AS PER A300 AMM 06-31-55-00 AND EA NO 6-5520-T0355929 P(1). THIS REPAIR IS CAT. A.