What was found
TRAPPED WATER INDICATION ON ELEVATOR UPPER SKIN PANEL HONEYCOMB CORE CELLS. LOCATED AT 17 INCH OUTBOARD FROM RIB 2 AND 5.5 INCH FROM TRAILING EDGE ON LT HORIZONTAL STABILIZER (1 EA) (L=3 INCH. AND W=1 INCH). REPAIRED LT ELEVATOR UPPER SKIN PANEL HONEY COMB CELLS LOCATED AT 14.75 INCHES FROM ERIB 2 AND 4.5 INCHES FROM T/E ON LT HORIZONTAL STABILIZER, AS PER SRM A300-600 55-21-12 PAGE BLOCK 201 PARAGRAPH 5.J. EXACT LOCATION BETWEEN STA 168 AND STA 221, AS PER A300 AMM 06-31-55-00 AND EA 6-5520-T0355929 (P1). THIS REPAIR IS CAT-A.