What was found
TRAPPED WATER INDICATION ON ELEVATOR UPPER SKIN PANEL HONEYCOMB CORE CELLS. LOCATED AT 27 INCH OUTBOARD FROM RIB 13 AND 7 INCH FROM TRAILING EDGE ON LT HORIZONTAL STABILIZER (1EA) (L=2.25 INCH. W=1.5 INCH). REPAIRED LT ELEVATOR UPPER SKIN PANEL HONEYCOMB CORE CELLS LOCATED AT 27 INCHES OUTBOARD ERIB 13 AND 7.5 INCHES FROM T/E ON LT HORIZONTAL STABILIZER, AS PER SRM A300 55-21-12 PAGE BLOCK 201 PARAGRAPH 5.J. EXACT LOCATION IS BETWEEN STA 576 AND STA 633, AS PER A300 AMM 06-31-55-00 AND EA NO 6-5520-T0355929 P(1). THIS REPAIR IS CAT-A.