What was found
MAIN DECK BS 1015 BETWEEN LBL 24.75 - LBL 45.5 FLOORBEAM CORRODED. REMOVED THE CORROSION ON THE STRAP ONLY IAW SRM 51-10-02. ORIG MAT .012 REM .005 LOSS .007, FOUND OUT OF LIMITS IAW SRM 53-00-51-1A, FIG 101. REMOVED, FABRICATED AND INSTALLED A NEW STRAP IAW IAW SRM 51-40-02, 51-40-05, 51-40-08, AND DWG 144N5081, REV A & C.