What was found
MAIN DECK STA 1015 BETWEEN LBL24.75-LBL45.5 FLOOR SUPPORT CORRODED REMOVED CORR ON FLOOR SUPPORT STRAP ONLY IAW B757 SRM 51-10-02. ORIG MAT .012 REM .005 LOSS .007 FOUND OUT OF LIMITS IAW B757 SRM 53-00-51-1A FIG 101. REMOVE, FABRICATED AND INSTALLED NEW STRAP IAW B757 SRM 51-40-02, 51-40-05, 51-40-08 AND BOEING DWG 144N5081 REV A & C