What was found
R1 MAIN CABIN ENTRY DOOR SLIDE WILL NOT ARM. IAW TSM 52-70-00, CHECKED FOR GROUND AT R1 DOOR LIMIT SWITCHES. FOUND EXCESSIVE RESISTANCE AT PIN "E" OF LIMIT SWITCH 1 (42WS), AND OPEN FOUND AT PIN "E" OF LIMIT SWITCH 2 (8WS). NO TIME TO FURTHER TROUBLESHOOT DUE TO HIGHER PRIORITY MAINTENANCE. REMOVED AND INSTALLED BOTH 8WS AND 42WS SWITCHES IAW AMM 52-71-00-04-01, CHECKS GOOD