What was found
TRAPPED WATER INDICATION ON ELEVATOR UPPER SKIN PANEL HONEYCOMB CORE CELLS. LOCATED AT 9 INCH. OUTBOARD FROM RIB 7 AND 25 INCH. FROM TRAILING EDGE. REPAIRED THE ELEVATOR UPPER SKIN IAW SRM 55-21-12, PB 201, PARA 5.B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TRAPPED WATER INDICATION ON ELEVATOR UPPER SKIN PANEL HONEYCOMB CORE CELLS. LOCATED AT 9 INCH. OUTBOARD FROM RIB 7 AND 25 INCH. FROM TRAILING EDGE. REPAIRED THE ELEVATOR UPPER SKIN IAW SRM 55-21-12, PB 201, PARA 5.B.