What was found
TRAPPED WATER INDICATION ON THE LT ELEVATOR UPPER SKIN PANEL HONEYCOMB CORE CELLS. LOCATED 9 INCHES INBOARD FROM RIB 5 AND 13 INCHES FROM TRALING EDGE. REPAIRED THE SKIN IAW SRM 55-21-12, PAGE BLOCK 201, PARAGRAPH 5.J.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TRAPPED WATER INDICATION ON THE LT ELEVATOR UPPER SKIN PANEL HONEYCOMB CORE CELLS. LOCATED 9 INCHES INBOARD FROM RIB 5 AND 13 INCHES FROM TRALING EDGE. REPAIRED THE SKIN IAW SRM 55-21-12, PAGE BLOCK 201, PARAGRAPH 5.J.