What was found
MAIN DECK BS 1661 BL 0 FLOORBEAM TEE FITTING CORRODED. REMOVED CORROSION IAW SRM 51-10-02-0G. EVALUATED DAMAGED AREA ORIG. MAT.=.125", REM. MAT.= .106", MAT. LOSS= .019" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51-1A, FIG 101, DETAIL VI. FABRICATED AND INSTALLED A REPAIR ANGLE AND FILLERS IAW SRM 53-00-51-2R, FIG 201. DETAIL I, REPAIR 11.