What was found
MAIN DECK BETWEEN STA 1681 - 1720 BL 0 - RBL 58.22 WEB CORRODED FABRICATED AND INSTALLED 1EA REPAIR DOUBLER ON AFT MAIN DECK PLATE AT STA 1681, RBL 24.75 IAW B757 SRM 53-60-51-2R FIG 201 DETAIL I REPAIR 2 ALTERNATIVE I. REMOVED CORROSION ON DECK PLATE AT STA 1681-1720, BLO-RBL 58.22 IAW B757 SRM 51-10-02-0G. EVALUATED DAMAGED AREA AT STA 1681 RBL 24.75 ORIG MAT. = .071", REM. MAT. = .048", MAT. LOSS = .023" FOUND TO BE OUT OF LIMITS IAW B757 SRM 53-00-51-1A, FIG 101 DET III. ALL OTHER AREAS AT ST. 1681-1720, BL0-RBL588 FOUND TO BE WITHIN LIMITS IAW B757 SRM 53-00 00-51-1A FIG 101 DETAIL II