What was found
MAIN DECK BETWEEN STA 1681 - 1720 BL 0 - LBL 58.22 WEB CORRODED FABRICATED AND INSTALLED 1EA REPAIR DOUBLER ON AFT MAIN DECK PLATE AT STA 1681 LBL 24.75 IAW B757 SRM 53-60-51-2R FIG 201 REPAIR 2 ALTERNATIVE I. REMOVED CORROSION ON DECK PLATE AT STA 1681-1720 , BL0 - LBL58.22 IAW B757 SRM 51-10-02-0G. EVALUATED DAMAGED AREA AT STA 1681 LBL 24.75 ORIG. MAT. = .071", REM. MAT. =.049", MAT. LOSS= .022" FOUND TO BE OUT OF LIMITS IAW B757 SRM 53-00-51-1A FIG 101 DETAIL III, ALL OTHER AREA AT STA 1681-1720 BL0 - LBL 58.22 FOUND TO BE WITHIN LIMITS IAW B757 SRM 53-00-51-1A FIG 101 DETAIL III.