What was found
CRACK TRAILING EDGE IN OVERWING PANEL BEAM 5 ON RT WING. PERFORMED PERMANENT REPAIR LOC. TRAILING EDGE IN OVERWING PANEL BEAM 5 ON RT WING, IAW EA 6-5720-T0355567 A WING. SECONDARY STRUCTURES TRAILING EDGE STRUCTURES OVER MLG BAY, INBOARD SHROUD, CRACK, PERMANENT REPAIR.