What was found
LOWER FUSELAGE CENTER ACCESSORY COMPARTMENT FLOOR LONGERON NR 51 LEFT FOUND WITH CORROSION STATION 1139. LOWER FUSELAGE CENTER ACCESSORY COMPARTMENT FLOOR LONGERON NR 51 LEFT STATION 1139 AREA CORROSION. REMOVED FOUND EXCEED LIMIT, AS PER SRM 53-00-00-2R FIGURE 205. REPAIR GENERAL AND LONGERON 51 LEFT REMOVED AND REPLACED, AS PER SRM 51-33-01- 0G. FABRICATED LONGERON 51 LEFT, AS PER DOUGLAS DRAWING AAA7086 REVISION NEW. REPAIR CLASSIFIED AS MAJOR, PER GMM 6-2-100.