What was found
UPON REMOVAL OF LEFT HAND NOSE LANDING GEAR TRUNNION BUSHING (REFERENCE SNRM N00321) FOUND BORE SURFACE WITH CORROSION. LEFT HAND NOSE LANDING GEAR TRUNNION BORE SURFACE REWORKED AND FOUND EXCEED LIMIT, AS PER MD-11 SRM 53-10-14-2R FIGURE 201 REPAIR 1. OVERSIZE BUSHING 02 EACH FABRICATED BY MACHINING, AS PER MD-11 SRM 53-10-14-2R FIGURE 201 REPAIR 1. FABRICATED REPAIR BUSHINGS 02 EACH INSTALLED, AS PER MD-11 SRM 53-10-14-2R FIGURE 201 REPAIR 1 AND EA NR 1-5310-T0357292 PART 1 STEP 1. TITLE: FUSELAGE-MAINFRAME-LT NLG TRUNNION FITTING BORE HOLES ELONGATED AT STA 587-MD11 SRM 53-10-14 REPAIR 1- ALTERNATE CADMIUM PLATING PROCESS. REPAIR CLASSIFIED AS MINOR, PER GMM 6-2-100.