What was found
MAIN DECK FR47 Y953~Y1456 UNDERFLOOR WEB CRACKED REPAIRED THE MAIN DECK FR47 Y953~Y1456 UNDERFLOOR CRACKED WEB PER A300-600 SRM53- 15-15 FIG201 SHEET 2 , THIS IS CATEGORY B REPAIR AND IT MUST BE INSPECTED AT DEFINED INTERVALS PER A300-600 SRI 53-15-15-2-001-00. INSPECTION THRESHOLD FROM REPAIR EMBODIMENT IS 24000FC. SUBSEQUENT INSPECTION AT INTERVAL OF 3000FC UNTIL 51000FC. INSPECTION METHOD: DETAILED VISUAL. MAJOR REPAIR IAW FEDEX GMM6-2-100.