What was found
CRACK INDICATION FOUND APPROXIMATELY 0.125 INCHES IN LENGTH DURING HIGH FREQUENCY EDDY CURRENT INSPECTION ON LEFT HAND SIDE NOSE LANDING GEAR TRUNNION FITTING EXISTING TRIM OUT AT STATION 583. LEFT HAND SIDE NOSE LANDING GEAR TRUNNION FITTING EXISTING TRIM OUT AT STATION 583 CRACK APPROXIMATELY 0.125 INCHES. CARRIED OUT REPAIR, AS PER EA NR: 1-5310-T0312012A PART 3. TITLE: FUSELAGE-MAIN FRAME-LT NLG TRUNNION FITTING CRACK INSPECTION. REPAIR CLASSIFIED AS MAJOR, PER GMM 6-2-100.