What was found
AFT CARGO COMPARTMENT STATION 1902.15 X=18 TO -18 FLOOR PANEL SUPPORT FOUND CORRODED. AFT CARGO COMPARTMENT STATION 1902.15 X=18 TO -18 FLOOR PANEL SUPPORT. CORROSION REMOVED FOUND EXCEED LIMIT AS SRM 53-00-00-2R FIGURE 206 REPAIR GENERAL. REPAIRED AS PER EA: 1-5321-T0358320 P1. TITLE: FUSELAGE-CARGO COMP FLOORS-AFT CARGO COMPARTMENT-STA 1902.150 FLOOR BEAM-CORROSION FOUND ON ANGLE BETWEEN X=20 AND X= -20. REPAIR CLASSIFIED AS MAJOR, PER GMM 6-2-100.