What was found
MAIN CABIN FLOOR PANEL SUPPORT UPPER SURFACE IS CORRODED AT FASTENER HOLE BS 1663-RBL 54. REMOVED CORROSION, IAW B757 SRM 51-10-02, ORIG MAT .071", REMOVED MAT .003", REMAINING MAT .068". FOUND TO BE WITHIN LIMITS, IAW BOEING DWG 657N4303 REV B AND B757 SRM 53-60-15-1A DETAIL III. TREATED BARE METAL, IAW B757 SRM 51-20-01.