What was found
FLOOR PANEL SUPPORT UPPER SURFACE IS CORRODED AT FASTENER HOLE BS 1642-BS 1658, RBL 54. REMOVED CORROSION, IAW B757 SRM 51-10-02, ORIG MAT .071", REMOVED MAT .003", REMAINING MAT .068". FOUND TO BE WITHIN LIMITS, IAW BOEING DWG 657N4303 REV B, B757 SRM 53-60-15-1A, TREATED BARE METAL, IAW B757 SRM 51-20-01.