What was found
BATTERY CHARGER/APU START ELECTRICAL BAY, JUST BELOW POWER CENTER, SMELLED ELECTRICAL BURNING. REMOVED PANEL AND FOUND BURNT WIRING FROM R2-24 POSITION A2 TO B1-114 POSITION A1. WILL INCLUDE PICTURES. PARTS NEEDED. WE NEED WIRE NR C904-26-6 FABRICATED, REF MD-11 WIRING DIAGRAM MANUAL. WIRE LIST SECTION C0900 PAGE 86. WE HAVE RCCB B1-114 CPN 0046345. R & R BAT CH RELAY R2-24, PER AMM 24-34-01. R & R BAT CH RCCB B1-114, PER AMM 24-50-01. REPLACED BUS BAR & BURNED WIRE, PER SWP. BAT CHARGER OPERATIONS TEST, GOOD PER AMM 24-34-03. OK FOR SERVICE.