As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
L-1 ENTRY DOOR EVAC SLIDE REMOTE PRESS INDICATOR DOES NOT TEST. L-1 ENTRY DOOR EVAC SLIDE REMOTE PRESS INDICATOR INOP. REMOVED AND REPLACED REMOTE PRESSURE INDICATOR ASSEMBLY PER MD11 AMM 25-61-04-4 AND MD11 IPC 25-61-05-01 ITEM 160. PERFORMED OPERATIONAL TEST OF THE REMOTE PRESSURE INDICATOR IAW MD11 AMM 25-61-04-5. OPERATIONAL TEST PASSED.