What was found
MAIN DECK STA 1055 LBL 43 FLOOR SUPPORT HAS A PUNCTURE HOLES. EVALUATED FLOOR SUPPORT AT MAIN DECK STA 1055 LBL 43,FOUND DAMAGE ONLY ON CO COVER COVER PLATE IAW B 757 SRM 51-10-02-OG,FABRICATED AND INSTALLED NEW COVER PLATE IAW B 757 SRM 51-40-02-OG AND BOEING DWG # 144N5070 REV: B AND W.