What was found
HIGH FREQUENCY EDDY CURRENT INSPECTION CARRIED OUT ON RIGHT HAND NOSE LANDING LANDING GEAR TRUNION FITTING AND FOUND 01 EACH CRACK APPROXIMATELY 0.1 INCH PROPAGATE PROPAGATE FROM THE SLOT AREA AT STATION Y=595. RIGHT HAND NOSE LANDING GEAR TRUNION FITTING AT STATION Y=595 CARRIED OUT REPAIR IN ACCORDANCE WITH EA NUMBER 1-5310-T0315112 A PART 3. TITLE: " FUSELAGE - MAIN FRAME - RH NLG TRUNION FITTING CRACK INSPECTION". REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.