What was found
MAIN DECK STATION 1921 TO 1941 LEFT HAND X = 57 FLOOR PANEL SUPPORT FOUND CORRODED. MAIN DECK STATION 1921 TO STATION 1941 LEFT HAND X = 57 AT FLOOR PANEL SUPPORT , CORROSION EVALUATED FOUND EXFOLIATED AND EXCEEDED LIMIT AS PER SRM 53-00-00-2R FIGURE 206 ALLOWABLE DAMAGE. CORRODED FLOOR PANEL SUPPORT REMOVED AND REPLACED FROM STATION 1887 TO STATION 2007, X = 57 AS PER SRM 51-31-01-0G. FLOOR PANEL SUPPORT FABRICATED BY MACHINIG AS PER DOUGLAS DRAWING AGA 7551 REVISION G. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.